=== HW Revision 1.1 ===
+
== FITPC4ERR001: Power LED ==
 
+
* '''Date''':
1. ''Power LED''
+
* '''Symptom''': Power (Logo) LED enabled at all power states (S0, S3, S4 and S5), even during SW shut down
* '''Bug''': Power (Logo) LED enabled at all power states (S0, S3, S4 and S5), even during SW shut down
+
* '''Applies to revision(s)''': 1.0 to 1.1
 +
* '''Cause''': Incorrect LED connection
 +
* '''Workaround''': Ignore logo LED indications
 
* '''Fix''': Fixed in revision 1.2
 
* '''Fix''': Fixed in revision 1.2
  
 
+
== FITPC4ERR002: Memory organization ==
2. ''Memory organization''
+
* '''Date''':
* '''Bug''': When single memory module installed on inner slot (P6) it may cause the system not to pass memory initialization
+
* '''Symptom''': When single memory module installed on inner slot (P6) it may cause the system not to pass memory initialization
* '''Fix''': In case single SO-DIMM to be used, it should populate the slot closer to an edge (P7) of the PCB
+
* '''Applies to revision(s)''': 1.0 to 1.1
 
+
* '''Cause''': Incorrect SIM slot pin routing
 +
* '''Workaround''': In case single SO-DIMM to be used, it should populate the slot closer to PCB edge (P7)
 +
* '''Fix''': Populate the slot closer to PCB edge (P7)
  
  
 
[[category:fit-PC4]]
 
[[category:fit-PC4]]

Revision as of 10:08, 11 October 2015

FITPC4ERR001: Power LED

  • Date:
  • Symptom: Power (Logo) LED enabled at all power states (S0, S3, S4 and S5), even during SW shut down
  • Applies to revision(s): 1.0 to 1.1
  • Cause: Incorrect LED connection
  • Workaround: Ignore logo LED indications
  • Fix: Fixed in revision 1.2

FITPC4ERR002: Memory organization

  • Date:
  • Symptom: When single memory module installed on inner slot (P6) it may cause the system not to pass memory initialization
  • Applies to revision(s): 1.0 to 1.1
  • Cause: Incorrect SIM slot pin routing
  • Workaround: In case single SO-DIMM to be used, it should populate the slot closer to PCB edge (P7)
  • Fix: Populate the slot closer to PCB edge (P7)