FITPC4ERR001: Power LED
- Date: 28-Apr-2014
- Symptom: Power (Logo) LED enabled at all power states (S0, S3, S4 and S5), even during SW shut down
- Applies to revision(s): 1.0 to 1.1
- Cause: Incorrect LED connection
- Workaround: Ignore logo LED indications
- Fix: Fixed in revision 1.2
FITPC4ERR002: Memory organization
- Date: 22-Jul-2014
- Symptom: When single memory module installed on inner slot (P6) it may cause the system not to pass memory initialization
- Applies to revision(s): 1.0 to 1.1
- Cause: Incorrect SIM slot pin routing
- Workaround: In case single SO-DIMM to be used, it should populate the slot closer to PCB edge (P7)
- Fix: Populate the slot closer to PCB edge (P7)
FITPC4ERR003: RTC Battery
- Date: 11-Feb-2018
- Symptom: fit-PC4 circuit of RTC battery-on-a-wire has reversed polarity. fit-PC4 that is disconnected from power will exhibit the following behavior:
- Time and date will be reset.
- Customized BIOS settings will be reset to default.
- Applies to Serial(s): 1170622-21561 to 1180118-00301
- Cause: RTC battery-on-wire with incompatible polarity installed in the fit-pc4.
- Workaround: The problem can be addressed by replacing the RTC battery with a battery having compatible polarity to fit-PC4.
- Please contact Compulab fit-PC technical support (support@fit-pc.com +972-4-8290134) to address the issue.
- Fix: fit-pc4 serials 1180118-00301 and later manufactured with compatible polarity RTC battery-on-wires.
- Reference: Fit-PC4 RTC Battery Erratum