== FITLET2ERR001: No eMMC support ==
+
__TOC__
 +
 
 +
== FITLET2ERR001: Power button action cannot be configured in Windows 10 ==
 +
* '''Date''': 27-May-2018
 +
* '''Symptom''': Configuring Power button action through Windows 10 control panel has no effect
 +
* '''Applies to''': fitlet2 rev 1.1
 +
* '''Cause''': Erratum in power management integrated circuit
 +
* '''Workaround''': Control power modes from software
 +
** [[fitlet2 Rev1.1 Power button action workaround for Windows 10]]
 +
* '''Fix''': Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00
 +
 
 +
== FITLET2ERR002: No eMMC support ==
 
* '''Date''': 2-Sep-2018
 
* '''Date''': 2-Sep-2018
 
* '''Symptom''': eMMC module is not identified
 
* '''Symptom''': eMMC module is not identified
* '''Applies to''': fitlet2 with serial number 1180902-xxxxx or earlier
+
* '''Applies to''': fitlet2 with SBC serial number 1180902-xxxxx or earlier
 
* '''Cause''': Circuit of eMMC interface is not assembled on SBC
 
* '''Cause''': Circuit of eMMC interface is not assembled on SBC
 
* '''Workaround''': Use M.2 SATA storage
 
* '''Workaround''': Use M.2 SATA storage
* '''Fix''': Fixed in fitlet2 with serial number 1180903-xxxxx and later
+
* '''Fix''': Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later
 +
 
 +
== FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) ==
 +
* '''Date''': 23-Oct-2018
 +
* '''Symptom''': When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state
 +
* '''Applies to''': fitlet2 rev 1.1 with serial number 1180724-xxxxx or earlier
 +
* '''Cause''': An erratum in fitlet2 PMIC
 +
* '''Workaround''': Long press on power button shuts down fitlet2 completely
 +
* '''Fix''': A new version of PMIC used in fitlet2 with serial number 1180725-00001 and later
 +
 
 +
Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003
 +
 
 +
== FITLET2ERR004: Marginal edge-connector quality in FC-PCI ==
 +
* '''Date''': 6-Jan-2019
 +
* '''Symptom''': Devices installed on FC-PCI (Modem / SSD / Wi-Fi adapter / mini-PCIe card) may malfunction. There is no record of permanent damage to devices installed on FC-PCI
 +
* '''Applies to''': fitlet2 with FC-PCI rev 1.0
 +
* '''Cause''': Marginal quality of FC-PCI edge connector
 +
* '''Workaround''': Covered under warranty. Compulab will replace FC-PCI FACET Cards exhibiting errors
 +
* '''Fix''': Compulab redesigns FC-PCI FACET Card (rev 1.1) to improve edge connector's quality
 +
 
 +
Note: The problem is specific to FC-PCI and does not apply to other FACET Cards
 +
 
 +
== FITLET2ERR005: Built in Ethernet port is disappearing on start-up ==
 +
* '''Date''': 28-Apr-2019
 +
* '''Symptom''': One of the built in Ethernet ports is disappearing on start-up.
 +
* '''Applies to''': fitlet2 configured with either - FC-PCI Rev1.0-1.1, FC-CEM Rev1.0, FC-POED Rev1.0.
 +
* '''Cause''': In FC-PCI Rev1.0-1.1, FC-CEM Rev1.0 and FC-POED Rev1.0 rails 3.3V_A and 3.3V_S are connected in way which affects power sequencing. As a result, in rare cases on-board Ethernet controller's reset is released before PCI bus initialization is complete which results in Ethernet controller being unrecognized.
 +
* '''Workaround''': None
 +
* '''Fix''': Fix applied to FC-PCI Rev1.2, FC-CEM Rev1.1, FC-POED Rev1.1.
 +
 
 +
== FITLET2ERR006: RS-485 half duplex not working on fitlet2 configured with FC-SCG==
 +
* '''Date''': 28-Apr-2019
 +
* '''Symptom''': RS-485 half duplex is not working on fitlet2 configured with FC-SCG.
 +
* '''Applies to''':fitlet2 configured with FC-SCG Rev1.0
 +
* '''Cause''': In FC-SCG Rev1.0 a signal that controls RX/TX direction is disconnected. As a result RS485 half-duplex does not function.
 +
* '''Workaround''': None
 +
* '''Fix''': Fix applied to FC-SCG Rev1.1
  
 
[[category:fitlet2]]
 
[[category:fitlet2]]
[[category:errata]]
+
[[category:errata notes]]

Revision as of 05:40, 30 April 2019

FITLET2ERR001: Power button action cannot be configured in Windows 10

  • Date: 27-May-2018
  • Symptom: Configuring Power button action through Windows 10 control panel has no effect
  • Applies to: fitlet2 rev 1.1
  • Cause: Erratum in power management integrated circuit
  • Workaround: Control power modes from software
  • Fix: Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00

FITLET2ERR002: No eMMC support

  • Date: 2-Sep-2018
  • Symptom: eMMC module is not identified
  • Applies to: fitlet2 with SBC serial number 1180902-xxxxx or earlier
  • Cause: Circuit of eMMC interface is not assembled on SBC
  • Workaround: Use M.2 SATA storage
  • Fix: Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later

FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep)

  • Date: 23-Oct-2018
  • Symptom: When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state
  • Applies to: fitlet2 rev 1.1 with serial number 1180724-xxxxx or earlier
  • Cause: An erratum in fitlet2 PMIC
  • Workaround: Long press on power button shuts down fitlet2 completely
  • Fix: A new version of PMIC used in fitlet2 with serial number 1180725-00001 and later
Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003

FITLET2ERR004: Marginal edge-connector quality in FC-PCI

  • Date: 6-Jan-2019
  • Symptom: Devices installed on FC-PCI (Modem / SSD / Wi-Fi adapter / mini-PCIe card) may malfunction. There is no record of permanent damage to devices installed on FC-PCI
  • Applies to: fitlet2 with FC-PCI rev 1.0
  • Cause: Marginal quality of FC-PCI edge connector
  • Workaround: Covered under warranty. Compulab will replace FC-PCI FACET Cards exhibiting errors
  • Fix: Compulab redesigns FC-PCI FACET Card (rev 1.1) to improve edge connector's quality
Note: The problem is specific to FC-PCI and does not apply to other FACET Cards

FITLET2ERR005: Built in Ethernet port is disappearing on start-up

  • Date: 28-Apr-2019
  • Symptom: One of the built in Ethernet ports is disappearing on start-up.
  • Applies to: fitlet2 configured with either - FC-PCI Rev1.0-1.1, FC-CEM Rev1.0, FC-POED Rev1.0.
  • Cause: In FC-PCI Rev1.0-1.1, FC-CEM Rev1.0 and FC-POED Rev1.0 rails 3.3V_A and 3.3V_S are connected in way which affects power sequencing. As a result, in rare cases on-board Ethernet controller's reset is released before PCI bus initialization is complete which results in Ethernet controller being unrecognized.
  • Workaround: None
  • Fix: Fix applied to FC-PCI Rev1.2, FC-CEM Rev1.1, FC-POED Rev1.1.

FITLET2ERR006: RS-485 half duplex not working on fitlet2 configured with FC-SCG

  • Date: 28-Apr-2019
  • Symptom: RS-485 half duplex is not working on fitlet2 configured with FC-SCG.
  • Applies to:fitlet2 configured with FC-SCG Rev1.0
  • Cause: In FC-SCG Rev1.0 a signal that controls RX/TX direction is disconnected. As a result RS485 half-duplex does not function.
  • Workaround: None
  • Fix: Fix applied to FC-SCG Rev1.1